Product Overview

Projection3" (76mm) in undogged position2-5/8" (67mm) in dogged positionWarrantyOne year on electrified, componentsLifetime on hardware componentsMaximum Door Height7' (2134mm) - Standard8' (2438mm) - Optional10' (3048mm) - Optional (panic device only)Cove

  • Zero-Risk Assurance: Full-Refund Policy
  • No Shipping Fees Above 30
  • 2 Months to Decide. Returns Simplified.

Description

Projection

  • 3″ (76mm) in undogged position
  • 2-5/8″ (67mm) in dogged position

Warranty

  • One year on electrified, components
  • Lifetime on hardware components
  • Maximum Door Height

    • 7′ (2134mm) – Standard
    • 8′ (2438mm) – Optional
    • 10′ (3048mm) – Optional (panic device only)

    Cover

    Stainless steel, zinc

    Trim

    • Archer, August, Charles, Johnston, Joshua, Louis, Warren, William or Withnell lever with escutcheon trim
    • Pull plate trim (excluding 45PT)
    • Rim cylinder x optional pull

    Door Thickness

    1-3/4″ (44mm) – Standard

    Applications

    • Heavy duty commercial
    • NOT recommended for single-rabbet double egress frames
    • NOT recommended for doors with inset greater than 1/8″

    Fasteners

    • Wood and machine screws
    • Thru-bolts

    Stile Width

    • 4″ (102mm) minimum stile width required
    • All stile widths are measured from door edge

    OriginalName

    4501 CLB 36″ x 96″ US10B REV 3

    Latchbolt Type

    • Top – 1/2″ (13mm) throw, Pullman type with automatic dead-latching, stainless steel
    • Bottom – 1/2″ (13mm) throw, Pullman type, held retracted during door swing, stainless steel

    DOOR WIDTH in. – EXIT DEVICE

    36

    Cover Tube

    Aluminum

    ELECTRICS – EXITS

    NOT APPLICABLE

    ACCESSORIES – EXITS

    NOT APPLICABLE

    FINISHES – EXITS

    NOT APPLICABLE

    MISC. – EXITS

    NOT APPLICABLE

    DOOR HEIGHT in. – EXIT DEVICE

    96

    End Caps

    • Standard end cap (zinc)
    • OPTIONAL Flush end cap (zinc)

    RATINGS – EXITS

    STANDARD – NON-FIRE RATED

    Product Overview Grade 1 Concealed Vertical Rod Exit Device, Less Bottom Rod
    Functions:
    01 – Exit Only (device)
    Applications:

    • Heavy duty commercial
    • NOT recommended for single-rabbet double egress frames
    • NOT recommended for doors with inset greater than 1/8″

    Notes:

    • Center line prep is 40″ (1016mm) – If door prep elevation is lower, a longer top rod will need to be ordered
    • Recommended to be used on appropriately reinforced doors
    • NOT recommended for doors with inset greater than 1/8″, ex. double egress frames or jamb depths over 5-3/4″ or greater
    • A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device’s fire rating

    Certifications:

    • ANSI/BHMA A156.3-2014 Grade 1
    • UL305 Listed for Panic Hardware
    • UL/cUL Listed for up to 3 hours for “A” labeled doors up to 10′ in height
    • UL10C Positive Pressure Rated
    • UL10B Neutral Pressure Rated
    • Complies with ANSI A117.1 for accessible buildings and facilities

    Finishes:

    • US3, US4, US10B, US26, US26D, US32D, BLK
    • Trim not available in US32D

    Warranty:
    Lifetime
    Dogging:

    • Hex key dogging standard on panic rated devices
    • Cylinder dogging available on panic rated devices – specify “CD”. 3902 Mortise cylinder with standard cam sold separately. Cylinder Length of 1-1/8″ (29mm) – 1-3/8″ (35mm) is required.

    Door Width:

    • 36″ (914 mm) field sizeable to 30″ (762mm) panic-rated door and 28″ (711mm) fire-rated door
    • 48″ (1219 mm) field sizeable to 36″ (914mm) panic- or fire-rated door
    • Reference electrified exit device for door width specifications

    Notes:

    • Center line prep is 40″ (1016mm) – If door prep elevation is lower, a longer top rod will need to be ordered
    • Recommended to be used on appropriately reinforced doors
    • NOT recommended for doors with inset greater than 1/8″, ex. double egress frames or jamb depths over 5-3/4″ or greater
    • A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device’s fire rating

    Rod Length:

    • Rods for 7′ (2134mm) door – Standard
    • Rods for 8′ (2438mm) and 10′ (3048mm) doors – Optional
    • Door height of 7′ (2134 mm) requires 34-5/8″ (879 mm) top rod length
    • Door height of 8′ (2438mm) requires 46-5/8″ (1184mm) top rod length
    • Extension rod kits available 2′ (610mm) or 3′ (914mm)

    Strikes:

    • Stainless steel with plated rollers included standard with panic devices
    • Solid stainless steel included standard with fire rated devices
    • Top strike mortised into frame